Maintaining uptime on commercial packaged rooftop units requires immediate access to verified OEM replacement components. Because commercial HVAC manufacturers frequently consolidate or supersede component part numbers across production years, field mechanics frequently encounter discontinued part numbers on legacy equipment data plates.

The directory below provides verified manufacturer part numbers, superseded revision histories, electrical specifications, and direct authorized distributor inventory lookups for critical rooftop equipment.

1. Microcomputer & DDC Control Boards

Control boards manage unit logic, safety timing, multi-stage compressor staging, and fault reporting. Always verify supply voltage (24VAC ± 10%) before replacing suspected boards.

OEM Part # Component Description Equipment Application Electrical Specs Sourcing Action
031-02630-000 York Simplicity® Unit Control Board (UCB) York Millennium Z22, Z23, Z24 (25–40 Ton) & Predator 24VAC Input, Flash LED Diagnostics, Flash 1–14 Code Logic Check Inventory →
031-02630-002 York Simplicity Plus Controller (BacNet/Modbus) York Commercial RTU with BAS Integration (15–50 Ton) 24VAC, RS-485 MS/TP Communication Interface Locate Supplier →
MOD02687 Trane ReliaTel™ Refrigeration Module (RTRM) Trane Voyager & Precedent Commercial RTUs (3–50 Ton) 24VAC, 12VDC Sensor Bus, Multi-Stage DX Logic Locate Supplier →

2. Refrigerant Safety Switches (Pressure Cutouts)

Refrigerant pressure switches protect compressors against catastrophic loss of charge or dangerous head pressure buildup. Commercial switches utilize female 1/4" SAE flare connections with internal Schrader valve depressors.

OEM Part # Switch Function Cutout / Reset Pressure Reset Type Direct Order
025-41564-000 High Pressure Cutout Switch (R-410A) Cutout: 585 PSIG ± 10 / Reset: 435 PSIG Auto-Reset (Monitored by UCB) Order OEM Part →
025-29998-000 Low Pressure Loss of Charge Switch Cutout: 50 PSIG ± 5 / Reset: 90 PSIG Auto-Reset (15-min lockout) Order OEM Part →
025-41565-000 Manual Reset High Pressure Cutout Cutout: 630 PSIG (Emergency Secondary Limit) Manual Pushbutton Reset Order OEM Part →

3. Power Distribution & Phase Protection Controls

Scroll compressors are strictly uni-directional. Reverse rotation caused by phase reversal on 460V utility service will destroy compressor internal bearings within minutes.

OEM Part # Component Voltage & Contact Rating Protection Features Direct Order
024-35308-000 Commercial 3-Phase Monitor Relay 190–480VAC 3-Phase, SPDT 10A Output Phase Loss, Phase Reversal, 3% Voltage Unbalance Order Phase Monitor →
024-25841-000 Definite Purpose Contactor (3-Pole) 40 Amp Full Load, 600VAC, 24VAC Coil Silver-cadmium oxide contacts, sealed housing Order Contactor →

4. Condenser Fan Motors & Blower Components

Commercial rooftop fan motors operate continuously in ambient rooftop temperatures exceeding 130°F. Always replace motor run capacitors whenever replacing condenser fan motors.

OEM Part # Motor Description Electrical Specs Shaft / Mount Direct Order
024-25984-000 Condenser Fan Motor (1/2 HP) 460V, 1-Phase, 1075 RPM, 1.3 FLA 1/2" Dia. x 4" Length, Belly Band / Stud Mount Order Fan Motor →
028-12510-000 Industrial Blower Gripbelt (Matched Set) B-Section Classic V-Belt (B58 / B62) Oil and heat resistant, static conducting Order Belt Set →
025-41120-000 Commercial R-410A Balanced Port TXV 10–15 Ton Capacity, Internal Check Valve 7/8" ODF Inlet x 1-1/8" ODF Outlet Order TXV →

Need Part Installation or Emergency Commercial Tech?