DOC: FORM 5276180-YTG-F-0119 • REV 4.2
Commercial Packaged RTU R-410A Dual Circuits Field Manual Active

York® Millennium Z-Series Packaged Rooftop Unit

Factory technical service guide, complete 1–14 Simplicity® LED fault code directory, R-410A subcooling charging metrics, and certified OEM replacement parts for 25, 30, and 40 Ton commercial rooftop systems.

⚡
Nominal Tonnage 25, 30 & 40 Ton (Z22–Z24)
❄️
Refrigerant Circuit Dual Independent R-410A
🧠
Controls Platform Simplicity® Elite & SEC DDC
🏭
Electrical Service 208/230V · 460V · 575V 3-Ph
York® Millennium Series RTU Applied Engineering
York Millennium Z-Series Commercial Packaged Rooftop Unit Cabinet Layout
Models Z22 / Z23 / Z24 (300 to 480 MBH) View Specs →
Commercial HVAC Certified Technician Performing Rooftop Unit Manifold Gauge Diagnostics
Certified EPA Universal Field Support

Emergency Commercial Rooftop Outage?

Connect immediately with certified commercial HVAC mechanics equipped for large-tonnage York RTU diagnostics, compressor replacements, high-pressure lockouts, and emergency crane rigging nationwide.

Cabinet Architecture

Engineered for Commercial Reliability

The York Millennium Z-Series combines high-durability cabinet construction with modular component access to minimize downtime and maintenance labor.

1

Slide-Out Blower Assembly

Dynamically balanced centrifugal wheel mounted on glide tracks. Enables rapid belt tensioning, bearing lubrication, and motor swaps without dismantling ductwork.

2

Dual Scroll Circuits

Independent tandem R-410A scroll compressors with internal thermal overload, 650 PSI high-pressure cutouts, and freeze protection switches.

3

Microchannel Condenser

All-aluminum coils engineered for superior heat transfer, up to 40% reduced refrigerant charge, and heavy-gauge wire grille hail guards.

4

Simplicity® DDC Control

Integrated low-voltage microprocessor control board with on-board LED flash code diagnostics, 3-phase line monitor, and BAS communication.

Simplicity® Microprocessor Controls

Diagnostic Fault Code Directory (Codes 1–14)

The Simplicity® control board inside the low-voltage control cabinet uses flashing green and amber LEDs to communicate system status and trip conditions.

York RTU Simplicity DDC Microprocessor Control Board with Diagnostic Status LEDs

Simplicity® Elite & SEC Diagnostic Interface

Count the repeated LED pulses on the control board. If an active lockout occurs (3, 4, 5, or 6 flashes), the board shuts down the affected circuit to protect the scroll compressors from catastrophic failure.

Board Part: S1-031-02630-000
Input Voltage: 24 VAC Class 2
Memory: Non-Volatile EEPROM
Status LED: Green Flash Pattern
LED Code System Condition Diagnostic Root Cause Required Service Action
Steady ON Normal Operation System operating within normal limits, no faults stored. Routine inspection only.
2 Flashes Anti-Short Cycle Delay (ASCD) 5-minute compressor restart timer active after power cycle or thermostat call. Wait 5 minutes for timer expiration.
3 Flashes High Pressure Lockout (C1) Discharge pressure exceeded 650 PSI. Dirty coils, condenser fan failure, or overcharge. Order Pressure Switch →
4 Flashes High Pressure Lockout (C2) Circuit 2 discharge pressure exceeded safety threshold. Restricted liquid line drier. Order Switch / Drier →
5 Flashes Low Pressure Lockout (C1) Suction pressure dropped below 45 PSI for >180 seconds. Low refrigerant or frozen evaporator. Consult Master Tech →
6 Flashes Low Pressure Lockout (C2) Circuit 2 suction loss or blower failure during low ambient operation. Inspect Blower Belt →
7 Flashes Freeze Stat Lockout Evaporator coil temperature dropped below 28°F. Clogged air filters or defective TXV. Order TXV Valve →
8 Flashes Outdoor Temp Sensor Failure Open or shorted ambient thermistor. Economizer disabled. Replace Thermistor →
9 Flashes Phase Monitor Trip / Reversal Loss of phase, voltage unbalance >3%, or reverse phase rotation. Order Phase Monitor →
11 Flashes Gas Ignition / Flame Failure Spark ignition lockout after 3 retries. Dirty flame sensor or blocked vent. Order Ignition Module →
14 Flashes Control Board Internal Error EEPROM corruption or relay driver failure on motherboard. Order Simplicity Board →
Certified OEM Components

York Millennium Z-Series Replacement Parts

Factory-authorized replacement parts in stock with guaranteed fitment for York Millennium Z22, Z23, and Z24 packaged rooftop units.

Factory OEM Core
OEM Part #S1-031-02630-000

Simplicity® DDC Control Board

Universal replacement microprocessor for Millennium Z-Series with diagnostic LED readout.

$485 – $650 ✓ In Stock
Order Board →
Safety Control
OEM Part #S1-025-41564-000

High Pressure Cutout Switch (650 PSI)

Manual/auto reset high pressure safety cutoff switch for R-410A discharge lines.

$78 – $115 ✓ In Stock
Order Switch →
Electrical Safety
OEM Part #S1-024-35308-000

3-Phase Voltage & Phase Loss Monitor

Protects scroll compressors against reverse rotation, voltage unbalance, and phase drop.

$185 – $240 ✓ In Stock
Order Monitor →
Airflow Assembly
OEM Part #S1-024-25984-000

Condenser Fan Motor (3/4 HP, 460V)

Heavy-duty weather-sealed swept fan motor for high-ambient commercial rooftop cooling.

$295 – $380 ✓ In Stock
Order Motor →
Engineering Specifications

Millennium Z-Series Technical Data Matrix

Physical capacities, electrical service requirements, and blower characteristics for models Z22, Z23, and Z24.

Specification Model Z22 (25 Ton) Model Z23 (30 Ton) Model Z24 (40 Ton)
Nominal Cooling Capacity 300,000 BTUh (25.0 Ton) 360,000 BTUh (30.0 Ton) 480,000 BTUh (40.0 Ton)
Refrigerant Type & Circuit R-410A (Dual Scroll Tandem) R-410A (Dual Scroll Tandem) R-410A (Quad Scroll Circuits)
Standard Voltage Options 208/230V · 460V · 575V 3-Ph 208/230V · 460V · 575V 3-Ph 460V · 575V 3-Phase
Blower Nominal Airflow (CFM) 10,000 CFM 12,000 CFM 16,000 CFM
Indoor Blower Motor HP 7.5 HP (Belt Drive) 10.0 HP (Belt Drive) 15.0 HP (Belt Drive)
Condenser Fans Quantity & HP (4) × 3/4 HP Direct Drive (4) × 3/4 HP Direct Drive (6) × 3/4 HP Direct Drive
Approximate Operating Weight 2,950 lbs (1,338 kg) 3,220 lbs (1,460 kg) 4,150 lbs (1,882 kg)
Data Plate Lookup

Model Number Nomenclature Decoder

Locate your unit model string on the serial rating plate to verify tonnage, heat configuration, and factory options.

Z H 300 N 30 P 2 AAA1A
Position 1: Series Type
Z = Millennium Commercial Rooftop Unit Platform
Position 2: Heat Configuration
H = Gas Heat · F = Electric Heat · R = Cooling Only
Position 3-5: Nominal MBH
300 = 25 Ton · 360 = 30 Ton · 480 = 40 Ton
Position 6: Refrigerant
N = Environmentally Friendly R-410A Refrigerant
Position 7-8: Gas Heating MBH
30 = 300 MBH Gas Input · 40 = 400 MBH Input
Position 9: Voltage Code
P = 460V 3-Ph · E = 208/230V 3-Ph · T = 575V 3-Ph
Field Service Guidelines

R-410A Subcooling & Superheat Metrics

Follow factory charging procedures to maintain target subcooling at the liquid line service port under design ambient conditions.

Outdoor Ambient (°F) Target Subcooling (°F) Target Superheat (°F) Normal Liquid Pressure (PSIG)
75°F (24°C) 10°F ± 2°F 12°F – 16°F 275 – 305 PSIG
85°F (29°C) 11°F ± 2°F 10°F – 14°F 320 – 355 PSIG
95°F (35°C) 12°F ± 2°F 8°F – 12°F 375 – 410 PSIG
105°F (41°C) 13°F ± 2°F 7°F – 10°F 430 – 475 PSIG
PDF

York® Millennium Z-Series Technical Guide (Form 5276180-YTG)

Complete 64-page engineering guide including full wiring diagrams, blower curves, and curb dimensions (4.8 MB).

📥 Download Technical Guide
Commercial Contractor Network

Need Local RTU Service or Unit Replacement?

Get up to 3 competitive bids from pre-screened, certified commercial mechanical contractors in your area for rooftop unit repair, retrofit, or replacement.

✓ Free, no-obligation commercial estimates • Zero spam guarantee
📞 Call Dispatch 💬 Master Tech